Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Chinese Journal of Medical Instrumentation ; (6): 160-163, 2022.
Article in Chinese | WPRIM | ID: wpr-928879

ABSTRACT

Body temperature is an essential physiological parameter. Conducting non-contact, fast and accurate measurement of temperature is increasing important under the background of COVID-19. The study introduces an infrared temperature measurement system based on the thermopile infrared temperature sensor ZTP-135SR. Extracting original temperature date of sensor, post-amplification and filter processing have been performed to ensure accuracy of the system. In addition, the temperature data of environmental compensation which obtained by polynomial fitting is added to the system to further improve measurement accuracy.


Subject(s)
Humans , Algorithms , Body Temperature , COVID-19 , Temperature , Thermometers
2.
Chinese Journal of Analytical Chemistry ; (12): 980-986, 2017.
Article in Chinese | WPRIM | ID: wpr-617628

ABSTRACT

Solid internal pressure is one of the important parameters in traffic bridge and defense field.However, the existing testing equipments have the defects of serious electromagnetic interference, poor reliability, and poor accuracy.To overcome the above problems, a fiber bragg grating (FBG) high pressure solid pressure sensor which used thin plates as elastic bearing diaphragm and applied the deflection under pressure to pull the pressure sensitive grating to realize pressure sensing axial displacement was designed.By calculating on the structure according to the measurement range and finite element simulation, its feasibility was confirmed.In the laboratory with constant temperature, the pressure calibration experiment was carried out, and the temperature compensation was performed by the temperature compensation grating in the same temperature field to correct the temperature drift of strain grating.Experimental results showed that the newly devised FBG pressure sensor could sense the pressure as high as 50 MPa, with a linearity of 99.2%.

3.
International Journal of Biomedical Engineering ; (6): 94-98, 2010.
Article in Chinese | WPRIM | ID: wpr-390130

ABSTRACT

Objective To develop one kind of mainstream ET-CO2 (carbon dioxide of the expiration tip)detector which provides accurate and real-time testing results. Methods Applying ADμC7026 as central processing unit for data pre-processing, temperature compensation algorithm and non-linear correction, the ETCO2 concentration, respiration waveform and respiration rate were obtained. Results The analyzing results of the experimental data shows that the system meets the design requirements with fine stability, rapid response, good repeatability and high accuracy. Conclusion ET-CO2 detector based on ADμC7026 makes the detection of CO2 more accurate and reliable, which provides more accurate real-time data for critical patient monitoring, anesthetic care, pediatric respiratory care and so on.

4.
Chinese Medical Equipment Journal ; (6)1989.
Article in Chinese | WPRIM | ID: wpr-594174

ABSTRACT

Objective To introduce a new kind of circuit with temperature and voltage double compensation function in view of the deficiency of ambient temperature change on existing respiratory signal detection circuit. Methods The respiratory signal is detected by the characteristics of diode junction voltage with temperature changes. Results The functions of automatic temperatures compensation and automatic voltage fluctuation compensation are realized with the differential connection of two identical diodes. Conclusion The experimental results shows that the proposed circuit is basically immune to the fluctuation of ambient temperature changes and voltage fluctuation, its structure is simple and the accuracy of breathing signal detection is also improved.

SELECTION OF CITATIONS
SEARCH DETAIL